´óÅïÎÂʪ¶È×Ô¶¯¿ØÖÆÏµÍ³

±¾ÎÄID:LW2588 ×ÖÊý:16442,Ò³Êý:52
´óÅïÎÂʪ¶È×Ô¶¯¿ØÖÆÏµÍ³

ÂÛÎıàºÅ:JD318        ×ÖÊý:16442,Ò³Êý:52

Õª   Òª
±¾Éè¼ÆÎªÒ»±Õ»·¿ØÖÆÏµÍ³£¬ÓÉ89C51µ¥Æ¬»ú£¬A/Dת»»µç·£¬Î¶ȼì²âµç·£¬Êª¶È¼ì²âµç·¡¢¿ØÖÆÏµÍ³×é³É¡£Î¶ȼì²âµç·½«¼ì²âµ½µÄζÈת»»³Éµçѹ£¬¸ÃÄ£Äâµçѹ¾­ADC0809ת»»ºó£¬½øÈë89C51µ¥Æ¬»ú£¬µ¥Æ¬»úͨ¹ý±È½ÏÊäÈëζÈÓëÉ趨ζÈÀ´¿ØÖÆ·çÉÈ»òµç¯Çý¶¯µç·£¬µ±ÅïÄÚζÈÔÚÉ趨·¶Î§ÄÚʱ£¬µ¥Æ¬»ú²»¶Ô·çÉÈ»òµç¯·¢³ö¶¯×÷¡£ÊµÏÖÁ˶ԴóÅïÀïÖ²ÎïÉú³¤Î¶ȼ°ÍÁÈÀºÍ¿ÕÆøÊª¶ÈµÄ¼ì²â£¬¼à¿Ø£¬²¢ÄܶԳ¬¹ýÕý³£Î¶ȡ¢Êª¶È·¶Î§µÄ×´¿ö½øÐÐʵʱ´¦Àí£¬Ê¹´óÅï»·¾³µÃµ½ÁËÁ¼ºÃµÄ¿ØÖÆ¡£
¸ÃÉè¼Æ»¹¾ßÓжÔζȵÄʵʱÏÔʾ¹¦ÄÜ£¬¶ÔÅïÄÚ»·¾³Î¶ȵÄÔ¤É蹦ÄÜ¡£
¹Ø¼ü´Ê£º89C51µ¥Æ¬»ú¡¢A/Dת»»¡¢Î¶ȼì²â¡¢Êª¶È¼ì²â¡¢¿ØÖÆÏµÍ³

 

Abstract
This design is on shutting the wreath the control the system, and be constituted by 89 C51s machine of single slice, A/ D convert electric circuit, temperature examine electric circuit, degree of humidity examine electric circuit, control system. Temperature examination electric circuit will temperature that examine conversion electric voltage, should imitate the electric voltage after ADC0809 convert, enter 89 C51 the machine of single slice, machine of single slice pass to more input the temperature and set up the temperature to control the fan or electric stove to move the electric circuit, and be room inside temperature is within the scope of enactment, single slice the wrong fan or electric stove of machine send out the action. Realizes to examination big room plant grew temperature and soil with air degree of humidity, supervise and control, and can right over the scope of normal temperature, degree of humidity that condition proceed the solid hour handle, made the big room environment to get the good control.
Should design to still have to temperature of solid hour show function, to room inside environment the preparing of temperature establish the function?                    
Key words£º89 C51s machine of single slice¡¢A/ D conversion¡¢temperature examination¡¢degree of humidity examination¡¢ control system

 


Ä¿    ¼
Õª   Òª 1
Abstract 2
Òý  ÑÔ 5
1   ¸ÅÊö 6
1.1ÎÒ¹úÉèʩũҵµÄ·¢Õ¹¶¯Ì¬ 6
1.2ÎÒ¹úÉèÊ©ÔÔÅàµÄÖ÷ÒªÀàÐÍ 7
1.3ÎÒ¹úÉèÊ©ÔÔÅà´æÔÚµÄÖ÷ÒªÎÊÌâ 8
1.4¶ÔÎÒ¹úÉèÊ©ÔÔÅàµÄ¼¸µã½¨Òé 9
1.5±¾Éè¼ÆµÄÊг¡Ç°¾° 10
2  ×Ô¶¯¿ØÖÆÏµÍ³µÄÉè¼Æ 11
3   ±ÈÀý΢»ý·Ö¿ØÖÆÔ­Àí 13
3.1  ±ÈÀý»ý·Öµ÷½ÚÆ÷ 13
3.2 PIDµ÷½ÚÆ÷ 13
4    ¿É¿Ø¹è¼°Æä¹¤×÷Ô­Àí 16
4.1¿É¿Ø¹è½á¹¹ 16
4.2¿É¿Ø¹è¹¤×÷Ô­Àí¼°ÌØÐÔ 16
4.3µ¥Ïà¿É¿Ø¹èÕûÁ÷µç· 19
5   ζȴ«¸ÐÆ÷ 21
5.1²¬µç×è 21
5.2ÈÈÃôµç×è 21
5.3 Èȵçż 22
5.4 °ëµ¼ÌåPN½áζȴ«¸ÐÆ÷ 24
6   Êýģת»»Ô­Àí 27
6.1 ¸ÅÊö 27
6.2 R£­2Rµ¹ TÐεç×èÍøÂçD/Aת»»Æ÷ 28
6.3 D/Aת»»Æ÷µÄÖ÷Òª²ÎÊý 29
7   ¾ßÌå·½°¸Éè¼Æ 31
7.1ʵʩ·½°¸¼°·ÖÎö 31
7.2µ¥Ôªµç·Éè¼Æ 32
½á  Êø  Óï 35
²Î¿¼ÎÄÏ× 36
¸½  ¼ 37
¸½Â¼Ò»  ¿ØÖÆÏµÍ³Ô´³ÌÐò 37
¸½Â¼¶þ  Õû»úµç·ͼ 49
¸½Â¼Èý  ǰÏò.ºóÏòµç·ͼ 50
¸½Â¼ËÄ  Ö÷°åµç·ͼ 51
Ö  л 52

ÏÂÔØµØÖ· WORD¸ñʽȫÎÄÏÂÔØÁ´½Ó(³äÖµ:128Ôª)


´óÅïÎÂʪ¶È×Ô¶¯¿ØÖÆÏµÍ³......
ÂÛÎÄÈ˹¤½µÖØ
±¾ÂÛÎÄ¡¶´óÅïÎÂʪ¶È×Ô¶¯¿ØÖÆÏµÍ³¡·ÔÚµç×Ó»úµç±ÏÒµÂÛÎÄÀ¸Ä¿£¬ÓÉµçÆø¹¤³ÌÂÛÎÄÍøÕûÀí,×ªÔØÇë×¢Ã÷À´Ô´ www.dqlunwen.top ¸ü¶àÂÛÎÄ,ÇëµãµçÆø¹¤³ÌÂÛÎIJ鿴
ÉÏһƪ£ºSMT¹¤ÒÕÁ÷³Ì¼°¸÷Á÷³Ì·ÖÎö½éÉÜ ÏÂһƪ£º»ùÓÚµ¥Æ¬»úµÄ¶ÌÐÅÊÕ·¢ÏµÍ³Éè¼Æ ¨..

µã»÷²é¿´¹ØÓÚ ´óÅïÎÂʪ¶È ×Ô¶¯¿ØÖÆÏµÍ³ µÄÏà¹ØÂÛÎÄÌâÄ¿ 2009-06-13 18:43:53¡¾·µ»Ø¶¥²¿¡¿
ÁªÏµ·½Ê½

Ïà¹ØÀ¸Ä¿

¹â»úµçÓ¦Óü¼Êõ
»úµçÒ»Ì廯
Ó¦Óõç×Ó¼¼Êõ
µç×ÓÐÅÏ¢¹¤³Ì¼¼Êõ
×Ô¶¯»¯Ãâ·ÑÂÛÎÄ
×Ô¶¯»¯×¨Òµ±ÏÒµÂÛÎÄ
µç×ÓרҵÃâ·ÑÂÛÎÄ
µç×Ó»úµç±ÏÒµÂÛÎÄ
µçÆø¹¤³ÌÃâ·ÑÂÛÎÄ
²â¿Ø¼¼ÊõÓëÒÇÆ÷
µçÆø¹¤³ÌÔ­´´ÂÛÎÄ
µç×ÓͨÐÅÂÛÎÄ
µçÆø×Ô¶¯»¯¿ªÌâ
µç×Ó»úµç¿ªÌⱨ¸æ
µç×ÓͨÐÅÃâ·ÑÂÛÎÄ
PLCÏà¹ØÍâÎÄ·­Òë
µç×Ó»úµçÐÅÏ¢ÍâÎÄ·­Òë
µç×ÓͨÐÅÍâÎÄ·­Òë
ÁªÏµ·½Ê½
µç×ÓÐÅÏ¢¹¤³ÌÂÛÎÄÏÂÔØ
µçÆø¹¤³ÌÂÛÎÄÏÂÔØ


ÁªÏµ·½Ê½


µçÆø¹¤³ÌÂÛÎÄÍøÌṩµçÆø¹¤³ÌÂÛÎÄ·¶ÎÄ,µçÆø¹¤³Ì±ÏÒµÂÛÎÄ,ÍøÕ¾ÓÀ¾ÃÓòÃûwww.dqlunwen.top 

±¾Õ¾²¿·ÖÎÄÕÂÀ´×ÔÍøÓÑͶ¸åÉÏ´«£¬Èç·¢ÏÖÇÖ·¸ÁËÄúµÄ°æÈ¨£¬ÇëÁªÏµÖ¸³ö£¬±¾Õ¾¼°Ê±È·Èϲ¢É¾³ý  E-mail: 17304545@qq.com

Copyright@ 2009-2022 µçÆø¹¤³ÌÂÛÎÄÍø °æÈ¨ËùÓÐ